Validation studies for Methamphetamine by using FTIR, GC-MS And UV-visible spectroscopy

dc.contributor.authorSameer, Muhammad
dc.date.accessioned2018-02-13T07:17:35Z
dc.date.available2018-02-13T07:17:35Z
dc.date.issued2017
dc.descriptionSupervised by:Dr. Khurram Shahzad Munawaren_US
dc.description.abstractBackground: Methamphetamine belongs to the class of amphetamine type stimulants. It is illicitly manufactured in clandestine laboratories. It is strong stimulant of central nervous system. Major precursors required for the manufacturing of methamphetamine includes ephedrine, pseudo-ephedrine and phenyl-2-propanone. Its manufacturing, possession, trafficking, distribution and sale have been restricted and controlled not only in Pakistan but internationally as well. Here we proposed a method for the detection and quantification of methamphetamine manufactured in Pakistan. The proposed method is quiet easy, simple, cost effective, require no complex methodology for sample preparation and its results are quiet reliable, accurate and reproducible. The detection or confirmation of methamphetamine was done by Gas Chromatography- Mass Spectrometry (GC-MS) and Fourier Transform Infrared Spectroscopy (FTIR).The quantification of methamphetamine was performed by using UV-Visible Spectrophotometer and all the parameters like accuracy, precision, linearity, reproducibility, limit of detection, limit of quantification etc were validated. The linearity range was 100 µg/ml to 1000 µg/ml and the observed lambda max was 259 nm. The proposed method is easy, simple, and accurate and results are so reliable that it can be used for the case work in forensics and for drug analysis. Methods: The presumptive color testing was used for the detection of methamphetamine. The confirmation of methamphetamine was done by Gas Chromatography- Mass Spectrometry (GC-MS) and Fourier Transform Infrared Spectroscopy (FTIR) and the quantification of methamphetamine was performed by using UV-Visible Spectrophotometer. Results: The linearity range was 100 µg/ml to 1000 µg/ml and the observed lambda max was 259 nm. The calibrators were stable for continuous 4 days. The limit of detection was 50 µg/ml and limit of quantification was 100 µg/ml. The absorbance showed by methamphetamine in UV-Visible range is due to π to π* transition. FTIR spectrum showed that sample was 88 % pure and that of GC-MS showed that sample contain 83% methamphetamine.en_US
dc.identifier.urihttps://escholar.umt.edu.pk/handle/123456789/2678
dc.language.isoenen_US
dc.publisherUniversity of Management and Technology Lahoreen_US
dc.subjectMethamphetamineen_US
dc.subjectPseudo-ephedrineen_US
dc.subjectMS Thesisen_US
dc.titleValidation studies for Methamphetamine by using FTIR, GC-MS And UV-visible spectroscopyen_US
dc.typeThesisen_US
Files
Original bundle
Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
Summary.pdf
Size:
236.08 KB
Format:
Adobe Portable Document Format
Description:
No Thumbnail Available
Name:
Full View.htm
Size:
23.33 KB
Format:
Hypertext Markup Language
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: